Research Article

Based on Revit Simulation to Propose a Green Building Design Proposal---Hotel in Merida, Mexico as an Example

Yijing Wang*
Tianjin University

* Corresponding author: [email protected]

Abstract

Building energy conservation is a hot topic of concern for the whole society. Numerous governments have introduced related policies. However, specific practice is rare. Therefore, a green hotel design study is developed whose core target is to improve buildings' cooling and heating energy efficiency. First, this article is based on the hot and humid tropical climate in Merida, Mexico. Second, the study is based on 3D modeling and energy simulation by Revit, comparing the influence on cooling and heating energy consumption of three kinds of building volumes, three types of glass and different orientations. The simulation conclusion indicates that the low and enclosed building, combined with double glass with high performance, low-E coating, high visible light transmittance and low solar heat gain coefficient, which is south-facing, performs at best comprehensively. However, this proposal is just a design conception. In the future, the real building needs to be monitored, including the court microclimate, indoor environment parameters and energy consumption in order to observe the actual effect of the energy conservation.

Keywords: 3D modeling; energy simulation; green hotel design; cooling and heating energy efficiency
Published: March 2, 2026
DOI: 10.54254/2753-7048/2026.ZJU31973
Volume: LNEP Vol.120
pp. 77-84
Download PDF

References

  1. Sharma, S. (2024) Green Materials & Construction: a Step towards Sustainable Environment. AIP Conference Proceedings, 3050 (1), 030009.
  2. Wang, Z.H. (2023) A Survey of Factors and Life Cycle Assessment in Selection of Green Construction Materials. Journal of Computational Intelligence in Materials Science, 16(1), 0.
  3. Alfouly, M. and Hamacher, T. (2025) Evaluating Urban Form Influence on Solar Exposure and Corresponding Building Energy Demands. European Geosciences Union General Assembly 2024, EGU24, 15532.
  4. Oladosu, T.L., Baheta, A.T. & Oumer, A.N. (2021) Desiccant Solutions, Membrane Technologies, and Regeneration Techniques in Liquid Desiccant Air Conditioning System. International Journal of Energy Research, 45(6), 8420–8447.
  5. Molina. & Mario, C. (2008) Green Building in North America. Paper 3a. Institutional Efforts for Green Building : the Case of Mexico / Centro Mario Molina. Montréal, Québec : Commission for Environmental Cooperation.
  6. Kirschner, V., Moravec, D., Macků, K., Kozhoridze, G. & Komárek, J. (2024) Comparing the Effects of Green and Blue Bodies and Urban Morphology on Land Surface Temperatures Close to Rivers and Large Lakes. Land, 13(2), 162.
  7. Samuelson, H., Srivastava, C. & Baniassadi, A. (2025) Optimizing Window Solar Heat Gain Coefficient for Energy and Carbon Performance in a Changing Context of Electrification and Decarbonization. Energy Reports, 13, 1450-1466.
  8. Malyarenko, V., Alyokhina, N. & Orlova, S. (2023) Methodology for Determining Heat Losses through Translucent Construction. Problems of the Regional Energetics, 83-98.
  9. Zhang, Z., Hui, H. & Song, Y. (2025) Response Capacity Allocation of Air Conditioners for Peak-valley Regulation Considering Interaction with Surrounding Microclimate. IEEE Transactions on Smart Grid, 16(2), 1155-1167.
  10. Karim, S.M.S., Kaplan, M.L., Lin, Y.-L. (2025) Urban Impacts on Convective Squall Lines over Chicago in the Warm Season—Part II: a Numerical Study of Urban Infrastructure Effects on the Evolution of City-scale Convection. Atmosphere, 16(6), 652.